Diebold Nixdorf Hardware-TSE
State of certification
Certification-ID of TSE according to chapter 9.2.2 of Anwendungserlass zu § 146a AO:
Certification-ID | Test item | Applicant | Date |
---|---|---|---|
BSI-K-TR-0393-2020 | Diebold Nixdorf TSE-CardVersion 1.0 | Diebold Nixdorf Systems GmbH | 20.02.2020 |
Certification identification
"BSI-K-TR-0393-2020" is returned for 'ftSignatureType' 0x4445000000000022
(certification identification).
Signature Creation Unit
Support
RC from version: 1.3.1
Stable from version: 1.3.6
The fiskaltrust.Middleware.SCU.DE.DieboldNixdorf package connects the middleware with a Diebold Nixdorf hardware-TSE via a serial COM port.
Parameters
Name | Description | Default Value Mandatory Field |
---|---|---|
ComPort | The COM port used for serial communication with the TSE | mandatory |
AdminUser | The username of the admin user. If not specified, the default value defined by the manufacturer is used. | to be documented optional |
AdminPin | Admin PIN of the TSE. If not specified, the default PIN is used. | to be documented optional |
TimeAdminUser | The username of the time-admin user. If not specified, the default value defined by the manufacturer is used. | to be documented optional |
TimeAdminPin | Time-admin PIN of the TSE. If not specified, the default PIN is used. | to be documented optional |
Troubleshooting
Problem | Possible cause | Solution |
---|---|---|
When starting the middleware, an error is displayed stating that access to the specified COM port was denied | Wrong COM port is used in the SCU configuration | Update SCU configuration with the correct COM port used |
COM port is already used by a software (typically by the Diebold Nixdorf Web Service included with the TSE) | The Diebold Nixdorf Web Service is not required as all access is made directly via the COM protocol. Uninstalling the Diebold Nixdorf software eliminates this problem. |